CCRJZ - 8702 HEAVY METAL REMOVAL

  • MSDS: CCRJZ
  • Manufacturer: NALCO CHEMICAL CO
  • Product Name: 8702 HEAVY METAL REMOVAL
  • National Stock Number: 6850-00N074247
Product Identification

Product ID:8702 HEAVY METAL REMOVAL
MSDS Date:05/28/1996
FSC:6850
NIIN:00N074247
MSDS Number: CCRJZ

Responsible Party
NALCO CHEMICAL CO
ONE NALCO CENTER
NAPERVILLE, IL 60563-1198
US

Emergency Phone: 708-920-1510

Info Phone: 708-305-1000

Preparer: WILLIAM W ULTRY

Cage: 89524

Contractor
ONDEO NALCO COMPANY
NAPERVILLE, IL 60563-1198 US

Telephone: (630) 305-1000

Cage: 89524

Ingredients

SODIUM HYDROXIDE (CERCLA)

CAS: 1310-73-2

RTECS: WB4900000

Fraction By Weight: <1%

OSHA PEL 2 MG/M3

ACGIH TLV: C 2 MG/M3

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


AND THE RELEASE OF TOXIC FUMES.

RTECS: 9999999ZZ


IF UNCON,

RTECS: 9999999ZZ


TANK TRUCK FOR DISP. FOR LGE INDOOR SPILLS,

RTECS: 9999999ZZ


CONTROL AND RECOVERY SHOULD WEAR THE PROTECTIVE

RTECS: 9999999ZZ


BEFORE DISP TO A LICENSED INDUS WASTE

RTECS: 9999999ZZ


A HAZARDOUS LIQUID WASTE CAN ALSO BE INCINERATED IN

RTECS: 9999999ZZ


NITRILE, PVC, NATURAL RUBBER, VITON AND BUTYL

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:NO Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: EYES/SKIN: MAY CAUSE IRRITATION
WITH PROLONGED CONTACT. CHRONIC: NONE SPECIFIED BY MANUFACTURER.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:A REVIEW OF AVAILABLE DATA DOES NOT IDENTIFY
ANY SYMPTOMS FROM EXPOSURE NOT PREVIOUSLY MENTIONED.
Medical Cond Aggravated by Exposure:A REVIEW OF AVAILABLE DATA DOES NOT
IDENTIFY ANY WORSENING OF EXISTING CONDITIONS.

First Aid

First Aid:EYES: IMMED FLUSH W/WATER FOR AT LEAST 15 MIN WHILE HOLDING
EYELIDS OPEN. CALL MD. SKIN: IMMED FLUSH W/WATER FOR AT LEAST 15
MIN. FOR LGE SPLASH, FLOOD BODY UNDER SHOWER. IF IRRIT PERSISTS,
CALL MD. I NGEST: DO NOT INDUCE VOMIT. GIVE WATER.CALL MD. INHAL:
REMOVE TO FRESH AIR. TREAT SYMPS. CALL MD. NOTE TO MD: BASED ON
INDIVIDUAL RXNS OF PATIENT, MD'S JUDGMENT SHOULD BE USED TO CTL
SYMPS (ING 3)

Fire Fighting

Flash Point Method:PMCC
Flash Point:NONE
Extinguishing Media:THIS PROD WOULD NOT BE EXPECTED TO BURN UNLESS ALL
THE WATER IS BOILED AWAY. REMAINING ORGS MAY BE IGNITABLE. (SUP
DAT)
Fire Fighting Procedures:WEAR NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:MAY EVOLVE NO*X OR SO*X UNDER FIRE
CONDITIONS. IF THE WATER IS DRIVEN OFF, THE REMAINING ORGANICS MAY
BE IGNITABLE.

Accidental Release

Spill Release Procedures:SML LIQ SPILLS: CONTAIN W/ABSORB MATL, SUCH AS
CLAY, SOIL/ANY COMMERCIALLY AVAIL ABSORB. SHOVEL RECLAIMED LIQ &
ABSORB INTO RECOVERY/SALVAGE DRUMS FOR DISP. LGE LIQ SPILLS: DIKE
TO PVNT FURTHER MOVEME NT & RECLAIM INTO RECOVERY/SALVAGE DRUMS/
(ING 4)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:AVOID CONTACT WITH SKIN, EYES AND
CLOTHING. DO NOT TAKE INTERNALLY.
Other Precautions:EMPTY CONTAINERS MAY CONTAIN RESIDUAL PRODUCT. DO NOT
REUSE CONTAINER UNLESS PROPERLY RECONDITIONED.

Exposure Controls

Respiratory Protection:RESPIRATORY PROTECTION IS NOT NORMALLY NEEDED
SINCE THE VOLATILITY AND TOXICITY ARE LOW. IF SIGNIFICANT MISTS ARE
GENERATED, USE EITHER A NIOSH APPROVED CHEMICAL CARTRIDGE
RESPIRATOR WITH A DUST/MIST PREFILTER OR SUPPLIED AIR.
Ventilation:GENERAL VENT IS RECOMMENDED. ADDITIONALLY, LOCAL EXHST VENT
IS RECOMMENDED WHERE VAPORS, MISTS/AEROSOLS MAY BE RELEASED.
Protective Gloves:IMPERMEABLE GLOVES (NEOPRENE, (ING 8)
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:EMERGENCY EYEWASH AND DELUGE SHOWER MEETING
ANSI DESIGN CRITERIA .
Work Hygienic Practices:IF CLOTHING IS CONTAMINATED, REMOVE CLOTHING &
THORO WASH THE AFFECTED AREA. LAUNDER CONTAMINATED CLOTHING BEFORE
REUSE.
Supplemental Safety and Health
PH: 11.5-13.0. EXTING MEDIA: USE WATER TO COOL CONTRS EXPOSED TO FIRE.
MATLS TO AVOID: OXYGEN, PERMANGANATES) WHICH CAN GENERATE HEAT,
FIRES, EXPLO & RELEASE OF TOX FUMES. AVOID CONT W/STRONG ACIDS (E
.G., SULFURIC, PHOSPHORIC, NITRIC, HYDROCHLORIC, CHROMIC, SULFONIC)
WHICH CAN GENERATE HEAT, SPLATTEING/BOILING (ING 2)

Chemical Properties

Spec Gravity:1.10-1.35
pH:SUPDAT
Solubility in Water:COMPLETELY
Appearance and Odor:HAZY, LIGHT YELLOW LIQUID, SULFUR ODOR

Stability

Stability Indicator/Materials to Avoid:YES
AVOID CONT W/STRONG OXIDIZERS (E.G., CHLORINE, PEROXIDES, CHROMATES,
NITRIC ACID, PERCHLORATES, CONCENTRATED (SUP DAT)
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:IN THE EVENT OF COMBUST CO, CO*2,
NO*X, SO*X MAY BE FORMED. DO NOT BREATHE SMOKE/FUMES. WEAR SUITABLE
PROT EQUIPMENT.

Disposal

Waste Disposal Methods:IF THIS PROD BECOMES A WASTE, IT MEETS THE
CRITERIA OF A HAZ WASTE AS DEFINED UNDER RCRA 40 CFR 261. HAZ WASTE
D002. AS A HAZ LIQ WASTE, IT MUST BE SOLIDIFIED W/STABILIZING
AGENTS (SUCH AS SAND, FLY A SH/CEMENT) SO THAT NO FREE LIQ REMAINS
(ING 6)

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their